关键词:PMU; 500kV 输电线路;故障定位;同步相量测量;行波算法;阻抗算法中图分类号:TM75 文献标志码:A 文章编号:1003-5168(2025)16-0009-04DOI:10.19968/j.cnki.hnkj.1003-5168.2025.16.002
PMU-basedFaultLocationMethodfor 500kV TransmissionLines
HONG Lei (State Grid Fujian Electric Power Co.,Ltd.,Uhv Branch,Fuzhou 35OoO1, China)
Abstract: [Purposes] To address the technical challenges of traditional 500kV line fault location methods,such as insuficient accuracy and high sensitivity to transition resistance,and to improve fault location accuracy and response speed. [Methods] PMU synchronous phasor measurement technology was adopted to obtain high-precision phasor data from both ends of the line through GPS clock synchronization. A fusion location algorithm combining traveling wave propagation theory and impedance calculation was designed,and the algorithm performance was verified through PSCAD/EMTDC simulation. [Findings] The simulation results show that the fusion algorithm controls errors within 0.68% ,with a response time of 11 ms,achieving a 35% accuracy improvement over traditional methods while demonstrating robust performance across various fault types.[Conclusions] This method effectively mitigates issues such as transition resistance effects and line parameter inaccuracies,achievesmillisecond-level fault location, and provides technical support for rapid grid fault recovery and smart grid development.
Keywords: PMU; 500kV transmission line; fault location; synchronous phasor measurement; traveling wavealgorithm;impedancealgorithm
0 引言
500kV 超高压输电线路在电力系统中承担着远距离传输电能的重要任务,其安全稳定运行直接影响电网供电可靠性。(剩余3356字)