纤维增强水泥基复合材料加固梁柱节点抗压性能分析
nalysis of Compresive Properties of Green FiberReinforced Cement-based Composite Reinforced Building Beam-columnJoints

打开文本图片集
中图分类号:TU528.041 文献标志码:A 文章编号:1005-8249(2025)01-0045-05
DO1:10.19860/j.cnki.issn1005-8249.2025.01.009
XIN Fang
(Shandong Fengze Engineering Project Management Co.,Ltd.,Weifang 261OOO,China)
Abstract:To improve thesafetyofreinforcedbeamcolumn joints,thecompressiveperformanceoffiber-reinforcedcementbased composite materialsreinforcedbeam columnjoints is studied.Produce4setsof specimens,1setofcommon beamcolumn joint specimens,and 3 sets of fiber-reinforced beam column joint specimens,with fiber volume contents of 1.0% , 1.5% , and 2.0% ,respectively. Compare the density,compressive performance,and bending performance of reinforced and unreinforced specimens. The research results show that the density of the reinforced specimens is relatively $\mathrm{\high{\it\Omega}}$ ,and the density of the fiber-reinforced beam column joint specimens with a fiber volume fraction of 1.5% is relatively high;The compressive strength of the specimen remains the highest after adding 1.5% composite material reinforcement;The decrease in elastic stiffessofallspecimensisslightlysmall,andafterreiforcement,theyarerelativelylessaffctedbypressre;The bending strengthrapidlydecreases during theinitial loading stage,and there isno significant decreasethereafter.However, afterreinforcement,thebendingstrengthofthespecimenreaches1MPa,indicatingasignificantlystrongerbendingcapacity. Whenreinforcing beam column joints withcement-basedcomposite materials,theoptimalcuring time is28days,andthemost suitable fiber volume fraction is 1.5% :
Key words:grenfiber;reinforced cement base;composite material;reinforcing buildings;beam-column joint;compresive performance
0 引言
梁柱节点是指在结构中梁和柱间的交汇部位,是常规建筑物中的一种连接形式[1-2]。(剩余6692字)