基于温湿度传感器的室内环境监测预警研究与应用

  • 打印
  • 收藏
收藏成功


打开文本图片集

中图分类号:TP212.1 文献标识码:A 文章编号:2096-4706(2025)23-0184-04

Abstract:Aiming at the problems that electronic sensors in indoor environmental monitoring are susceptible to electromagneticinterference,significanttemperatureandhumiditycrosstalk,andhighfalsealarmrateoffixedthreshold algorithm,acollborativesolutionbasedonFabry-Perotinterference-antiresonancecascadesensoranddynamictheshold adaptive algorithm is proposed.The experimental results show that the humidity sensitivity of the sensor is 1.4×10-7/%RH , the temperature crosstalk is only 0.20%/∘C ,and the24-hour drift is 0.05%RH .Underhigh temperatureandhighhumidity conditions,the sensitivity of 1.8×10-7/%RH and the stability of 0.08%RH/24 h can still be maintained. The corresponding dynamic thresholdadaptive algorithm performs wellincomplexscenariossuchas textile milsand hospitals.Itskeyindicators: false alarm rate of 2.8% ,falsenegative rate of 1.5% ,response delayof 4.2sand workingconditionadaptation time of 3.5min allreachtheleadinglevel.Thisstudyconstructsacomplete technologychain from precisionperception tointeligentdecisionmaking,and providesaninnovativesolutionforaccurateenvironmentalmonitoringinthefeldsofmedical treatmentandcultural security.

KeyWords: temperatureand humiditysensor;indoor environment;monitoringandearlywarning;FPI-AR;DTAA

0 引言

随着科技进步和人民生活水平的不断提高,大众对室内环境的要求越来越高,室内环境质量对人体健康、设备运行和文物保护具有至关重要的影响,特别是在医院、数据中心、博物馆等对温湿度要求严格的场所[1-2]。(剩余6072字)