基于ASM2d污水厂模型的构建及雨季流量冲击应对研究

  • 打印
  • 收藏
收藏成功


打开文本图片集

文章编号:1674-6139(2026)04-0073-06

中图分类号:X703文献标志码:B

AStudy on the Construction of ASM2d based Sewage Treatment Plant Model and Response to Rainy Season Flow Impacts

MuJunwei1,WangXinling²,DongJinbo³,YangTianyu1,YangBiao1 (1.Zhenjiang Water Supply and Drainage Management Office,Zhenjiang 212Oo1,China; 2.North China Municipal Engineering Design&Research Institute Co.,Ltd.,Tianjin 30o074,China; 3.Jiangsu Manjiangchun Urban Planning&Design Research Co.,Ltd.,Zhenjiang 212O01,China)

Abstract:ThisstudyutilizedtheASM2dmodeltosimulatetheperformanceofasewage treatmentplantin Zhenjiang,focusingon thesensitvityanalyssandcalibrationof1modelparametersTheresultsindicatedthatparameterssuchastheheterotrophicbacteria yield coeficient intheaerobic tank(YH_aerobic),themaximumgrowth rateof nitrifying bacteria( μAUT ),thedecayrateof nitrifying bacteria( bAUT ),andtheheterotrophicbacteriayieldcoeffcientintheanaerobictank(YHanaerobic)significantlyafectedtheffuent quality,including COD, NH3-N ,TSS,and TP.By optimizing these parameters,the predictive accuracy of the model was significantly improved.Furthermore,scenariossimulatingincreasedientflowuringtheinysasonweremodeled,evealingtheplant'sfo ancecharacteristicsinresponsetoseasoalfowfluctuations.ItwasfoundthattheTSSremovalefciencydecreasedslightlyduringthe rainyseason.Thestudyprovidesrecommendationstoitigatetheimpactofainysasonfuctuations,whichcanhelpehanethedapta bility and stability of sewage treatment processes.

Keywords:ASM2d model;sensitivity analysis;parameter calibration;seasonal flow fluctuations

前言

随着城市化的快速发展,城市排水系统的负荷不断增加,尤其是在雨季期间,压力尤为明显。(剩余5402字)