不同品牌注射器对注射泵流量误差的影响及校准建议

打开文本图片集
【摘要】本文结合日常校准工作经验和现场实验,对医用注射泵在使用不同品牌注射器情况下,分别选择通用注射器品牌模式与对应注射器品牌模式,探讨注射泵流量参数的误差及重复性后得出相关结论,对医用注射泵在日常校准工作对注射器品牌的选择及校准时其他注意事项给出建议。
【关键词】医用注射泵;流量;注射器品牌;建议
【DOI编码】10.3969/j.issn.1674-4977.2024.05.060
Influence of Different Trademarks Syringes on Syringe Pump Flow Errors and Calibration Recommendations
LIU Qi
(HainanAcademy of Inspection and Testing, Haikou 570206, China)
Abstract: In this paper, based on author’s routine calibration experience and field experiments, the relevant conclusions are drew on medical syringe pumps in the use of different brands of syringes, in the mode of respectively choosing a generic syringe brand and corresponding syringe brand to explore the errors and repeatability of the syringe pump flow parameters, and recommendations are given for the selection of syringe brands for routine calibration of medical syringe pumps and other considerations for calibration.
Keywords: medical syringe pump; flow; syringe trademarks; recommendation
医用注射泵是在医疗机构临床治疗及保健过程中使用范围非常广泛的医疗电子设备,主要应用于临床静脉输液的场景。(剩余3987字)