石蜡光安定性测定仪校准方法研究及其测量不确定度评定

  • 打印
  • 收藏
收藏成功


打开文本图片集

【摘要】本文参考SH/T 0404—2008《石蜡光安定性测定法》和GB/T 34097—2017《石油产品光安定性测定法》,对石蜡光安定性测定仪紫外辐照度和温度参数的校准方法进行了详细的介绍,采用直接测量法对其测量值进行不确定度评定,并进行分析。

【关键词】石蜡光安定性测定仪;校准;不确定度

【DOI编码】10.3969/j.issn.1674-4977.2023.04.013

Study on the Calibration Method of Paraffin Light Stability Tester and Its Measurement Uncertainty Evaluation

JIANG Tianqi, WANG Hao, LIU Yixuan

(Liaoning Institute of Measurement, Shenyang 110004, China)

Abstract: With reference to SH/T 0404—2008 Test method for light stability of paraffin wax and GB/T 34097—2017 Test method for light stability of petroleum products. This paper introduces in detail the calibration methods of ultraviolet irradiance and temperature parameters of the paraffin light stability tester, evaluates the uncertainty of the measured values by direct measurement, and analyzes them.

Key words: paraffin light stability tester; calibration; uncertainty

石蜡光安定性测定仪由带有数字显示的温度照度控制单元、紫外光照射加热单元、试样恒温照射室组成。(剩余2747字)