先导式低压输灰技术节能分析

打开文本图片集
[摘 要]河北华电石家庄鹿华热电有限公司输灰技术采用正压浓相双套管气力输灰技术,随着运行时间的增加,出现耗气量增加、输灰出力不足、管道和设备磨损严重等问题。文章对原输灰系统应用先导低压输送技术进行改造,并对其进行性能试验,从耗气量、输送压力、输送速度、出力及输送频次等方面与原输灰系统进行对比。
[关键词]先导低压输送技术;节气率;输送频次
[中图分类号]TM621 [文献标志码]A [文章编号]2095–6487(2024)06–0053–03
Energy-saving Analysis of Pilot Low-pressure Ash Conveying Technology
WANG Zheng,ZHAO Hang,XIE Chenchen,CHENG Liang,GUO Shunqiang
[Abstract]Hebei Huadian Shijiazhuang Luhua Thermal Power Co., Ltd. adopts a positive pressure dense phase double casing pneumatic ash conveying technology. With the increase of operating time, problems such as increased gas consumption, insufficient ash conveying output, and severe wear and tear of pipelines and equipment occur. The article renovates the original ash conveying system by applying pilot low-pressure conveying technology and conducts performance tests on it, comparing it with the original ash conveying system in terms of gas consumption, conveying pressure, conveying speed, output, and conveying frequency.
[Keywords]pilot low-voltage transmission technology; solar term rate; transmission frequency
1 原输灰系统概况和存在问题
河北华电石家庄鹿华热电有限公司2号机组容量 330 MW,采用1 170 t/h 亚临界压力、自然循环、一次中间再热、单炉膛、平衡通风、干式排渣、半露天布置、全钢构架的Ⅱ型汽包锅炉。(剩余2802字)