对JJF 1996-2022《瞳距仪检定装置校准规范》的内容探讨

  • 打印
  • 收藏
收藏成功


打开文本图片集

摘要:文中通过对JJF 1996-2022《瞳距仪检定装置校准规范》的简要介绍,讨论了使用投影仪和影像测量仪测量瞳距仪检定装置计量参数的各自优缺点,分析了标准套筒左右不对称性偏差和标准套筒左、右瞳距值之间的偏差计量术语的区别,建议增加“中心距测量结果一致性”计量特性。

关键词:瞳距仪检定装置;左、右瞳距值之间的偏差;中心距测量结果一致性

An Analysis of JJF 1996 -2022

"Calibration Specification for Pupilometer Distance Meter Verification Devices"

YANG Lingwen

( Putian Institute of Metrology, Putian 351100, Fujian, China )

Abstract:  Through the brief introduction of JJF1996-2022“Calibration specification of pupilometer verification device”, the merits and limitations of using projectors and image measuring instrument to measure the measurement parameters of pupilometer verification device are discussed. Specifically, this paper analyzes the difference between the measurement terms of the left-right asymmetry deviation and the left-right pupil distance of the standard sleeve. Based on this analysis, the paper recommends the inclusion of a new measurement characteristic: "the consistency of center distance measurement results." This addition aims to enhance the accuracy and reliability of pupilometer distance meter verification.

Key Words: Pupilometer distance meter verification devices; Left-right pupil distance deviation; Consistency of center distance measurements

0 引言

瞳距仪检定装置是用来检定瞳距仪的专用计量器具,可对瞳距仪的瞳距示值误差、不对称性误差等计量参数进行检定。(剩余3244字)