禁用偶氮染料测定中用内标2,4,5-三氯苯胺定量引入假阴性的研究


打开文本图片集

【摘要】 本文研究发现如果纺织品染色中使用了颜料红112,在用GCMS法测试纺织品种偶氮染料时,用2,4,5-三氯苯胺作为内标定量分析就容易产生假阴性干扰,影响禁用偶氮染料检出项的检测结果。

【关键词】 假阴性;颜料红112;2,4,5-三氯苯胺

【DOI编码】 10.3969/j.issn.1674-4977.2021.06.014

Study on the Quantitative Introduction of False Negatives with the Internal Standard 2,4,5-trichloroaniline in the Determination of Banned Azo Colourants

TIAN Xin-quan

(Bureau Veritas Commodity Inspection <Shanghai> Co.,Ltd.,Shanghai 201108,China)

Abstract: This study found that if pigment red 112 is used in textile dyeing, when using GCMS method to test textile azo dyes,using 2,4,5-trichloroaniline as an internal standard for quantitative analysis will easily produce false negative interference,which will affect the prohibition of couples. Test results of nitrogen dye detection items.

Key words: false negative;Pigment Red 112;2,4,5-Trichloroaniline

目前国家纺织品中偶氮染料的测定采用的最新标准是GBT 17592—2011《纺织品 禁用偶氮染料的测定》,该标准规定了两种仪器分析方法,而GCMS法用于偶氮染料的测试具有分析时间短、定性定量准确等优势。(剩余3972字)