1.Hubei Provincial Engineering Technology Research Center for Power Transmision Line,China Three Gorges University, Yichang 443O02, China;2. Collge of Electrical Engineering and New Energy,China Three Gorges University, Yichang 443002, China;3.State Grid Shiyan Power Supply Company,Shiyan 442000,China; 4.State Grid Handan Power Supply Company,Handan O56O35,China)
Abstract :For the problem that thermal-pressure effect (the high temperature and pressure)produced by arcing in the switchgear seriously threatens the safety of surounding buildings and staff,a calculation method of arcing thermal-pressure eect based on arc energy heat equivalence was proposed. Meanwhile, in order to reduce the harm of high temperature and high-speed airflow caused by short-circuit arcing process,the protective measures based on metal grid absorber were put forward. According to the action
principle of metal grid absorber,an equivalent mathematical model of metal grid absorber was constructed,and the influence of grid arrangement and placement location on the protection effect was analyzed. The results show thatthe pressure rise obtained by the arc energy heat equivalent method is in good agreement with the tests results,and the error is small.The metal grid absorber can effctively reduce the temperature and velocity of gas in the opening. The protection efect of the metal grid absorber with staggered arrangement is better,and the heat absorption efficiency is about 6,83% . The protective effect of the metal mesh absorber is better when it is close to the pressure relief opening. The research can provide a reference for the protection design of fault arcs in high-voltage switchgear.
Keywords:switchgear;short-circuit arcing;thermal-pressure effect;metal grid absorber;protection effect
0引言
金属封闭开关柜大量应用于输配电系统,是保障电力系统安全稳定运行的重要设备之一[1-2]。(剩余14144字)