基于时间差分变化量的串联电弧故障在线检测方法

  • 打印
  • 收藏
收藏成功


打开文本图片集

关键词:串联电弧故障;电弧电压;时间差分变化量;末端电压;电压变化率中图分类号:TM501.2 文献标志码:A 文章编号:2095-8188(2025)09-0013-14DOI: 10.16628/j .cnki.2095-8188.2025.09.002

Abstract:Thedetectionofseriesarc faultsisgreatlyaffectedbythetypeofload,and traditional fault detectionmethods thatusecurrentcharacteristicshave thedificultyofsetting thresholdcriteria.Inresponseto this issue,anonline detection methodforseriesarc faultsbasedonthetime diferencevariationof load side voltageis proposed.By identifying the presenceoffault arcvoltage inthe circuit,the arcfault detection isachieved.Byusing theadjacentwaveinspectionmode,thesuspectedarcfaultvoltagefaultsignalisdetected,andthenthereference waveform detection mode is triggered toconfirm thearc fault.The testresults show that the successrateof identifyingthenumberoffaultarcsofvariousloadsismore than 95% .With thedevelopment ofpowerInternet of Things and smart home technology,the proposed method provides a new idea for series arc fault detection.

Key words:series arc fault;arc voltage;time difference variation;terminal voltage;voltage change ratio

0 引言

电弧故障是低压配电线路中诱发电气火灾的重要原因。(剩余12794字)