中图分类号:TM732 文献标志码:A 文章编号:1000-582X(2026)03-038-11

doi:10.11835/j.issn.1000-582X.2024.222

引用格式:,,.电源"空心化"电网的协调二级电压控制优化方法[J].重庆大学学报,2026, 49(3): 38-48.

A decentralized coordinated optimization method for secondary voltage control in large urban power grids

WANG Xinling',YAN Wei',JIANG Wang²

(1. State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing

400044,P.R.China; 2.Electric Power Dispatchingand Control Center of State Grid Chongqing Electric Power Company, Chongqing 400014, P.R.China)

Abstract: Inlarge hubcitypower grids,load centers often lack flexible and continuouslyadjustable reactive power sources across multiple voltage levels,leading to a“holowing-out”of power supply.This paper proposes a coordinated two-level voltage control optimization method tailored for such“hollowed-out”power grids.In this method,thehigh-voltage busbar of all controlable power plants within a region are generalized as voltagedominant nodes,and regional voltage regulation is achieved by minimizing the sum of squared deviations between the busbar voltages and their reference values.Meanwhile,the coordination relationships among upper-level and lower-level regions are explicitly distinguished,and threshold-basedcontrol objectives between hierarchical regions are introduced to improve the reactive power supportcapabilityof lower-level areas.The effectiveness of the proposed method for regional reactive voltage control in holowed-out power networks is verified through simulations using a standard test system combined with actual grid data from China.

Keywords: secondary voltage control; automatic voltage control; coordinated control; AC-DC system

自动电压控制(automatic voltage control,AVC)是省级及以上电网的调度自动化系统。(剩余14342字)