有源医疗器械超温试验检测研究

  • 打印
  • 收藏
收藏成功


打开文本图片集

【摘要】本文参照GB 9706.1—2020《医用电气设备第1部分:基本安全和基本性能的通用要求》和GB 4793.1—2007《测量、控制和实验室用电气设备的安全要求第1部分:通用要求》,结合超温试验自身特点,对标准条款进行了梳理,总结出有源医疗器械超温试验的检测重点,以供相关人员参考。

【关键词】有源医疗器械;超温试验;检测

【DOI编码】10.3969/j.issn.1674-4977.2024.02.054

Research on the Detection of Overtemperature Test for Active Medical Devices

YANG Yan1*, SHENG Meina2, LUO Zhenhua3, ZHAO Xu1

(1.Liaoning Inspection,Examination & Certification Centre〔Liaoning Medical Device Test Institute〕, Shenyang 110036, China; 2. Alphavita Bio-scientific〔Dalian〕Co., Ltd., Dalian 116000, China; 3.Yisheng Dahua Petrochemical Co., Ltd., Dalian 116600, China)

Abstract: This article refers to the standard of GB 9706.1—2020 Medical electrical equipment—Part 1: General requirements for basic safety and essential performance and the standard of GB 4793.1—2007 Safety requirements for electrical equipment for measurement, control, and laboratory use—Part1:General requirements, combined with the characteristics of overtemperature test, the standard clauses were combed, and the key points of overtemperature test for active medical devices were summarized for reference.

Keywords: active medical devices; overtemperature test; detection

有源医疗器械按照执行电气设备安全标准可分为两种:1)医用电气设备;2)测量、控制和实验室用电气设备。(剩余3399字)